700 Series Windows

Our 700 series technical specs are listed below.  Feel free to contact our team if you’re interested in learning more about our customizable 700 series windows for your next commercial project.  These windows are offered in fixed and double hung models and have been used in numerous projects all over the United States.

FixedCasement
Frame Depth3.25"3.25"
Structural RatingClass AW-PG40Class AW-PG60
Test Size1524 x 2515 (60 x 99)914 x 1524 (36 x 60)
Design Pressure
ASTM E330
1920 Pa (40.10 PSF)2880 Pa (60.15 PSF)
Air Infiltration(ASTM E283)<0.01 L/s/m^2 (<0.01 CFM/ft^2) 300 Pa (6.27 PSF)0.05 L/s/m^2 (<0.01 CFM/ft^2) 300 Pa (6.27 PSF)
Water Resistance
(ASTM E547 and E331)
580 Pa (12.11 PSF)580 Pa (12.11 PSF)
Uniform Load Structural
(ASTM 330)
2880 Pa (60.15 PSF)4320 Pa (90.23 PSF)
U-Factor (NFRC | 100/200)
0.23 to 0.420.35 - 0.51
CRF (NFRC | 100/200)
Forced Entry Resistance
ASTM 588
Type D Grade 10Type B Grade 10
In-Swing CasementAwning
Frame Depth3.25"3.25"
Structural RatingClass AW-PG60Class AW-PG90
Test Size813 x 1835 (36 x 72-1/4)1524 x 813 (60 x 36)
Design Pressure
ASTM E330
2880 Pa (60.15 PSF)4320 Pa (90.23 PSF)
Air Infiltration(ASTM E283)0.2 L/s/m^2 (0.04 CFM/ft^2) 300 Pa (6.27 PSF)0.3 L/s/m^2 (0.05 CFM/ft^2) 300 Pa (6.27 PSF)
Water Resistance
(ASTM E547 and E331)
580 Pa (12.11 PSF)580 Pa (12.11 PSF)
Uniform Load Structural
(ASTM 330)
4320 Pa (90.23 PSF)6480 Pa (135.35 PSF)
U-Factor (NFRC | 100/200)
0.35 - 0.510.35 - 0.51
CRF (NFRC | 100/200)
Forced Entry Resistance
ASTM 588
Type B Grade 10Type B Grade 10
HopperSimulated DH Fixed
Frame Depth3.25"3.25"
Structural RatingClass AW-PG60Class AW-PG75
Test Size1524 x 965 (60 x 38)1524 x 2515 (60 x 99)
Design Pressure
ASTM E330
2880 Pa (60.15 PSF)3600 Pa (75.19 PSF)
Air Infiltration(ASTM E283)0.05 L/s/m^2 (<0.01 CFM/ft^2) 300 Pa (6.27 PSF)0.05 L/s/m^2 (<0.01 CFM/ft^2) 300 Pa (6.27 PSF)
Water Resistance
(ASTM E547 and E331)
580 Pa (12.11 PSF)580 Pa (12.11 PSF)
Uniform Load Structural
(ASTM 330)
4320 Pa (90.23 PSF)5400 Pa (112.79 PSF)
U-Factor (NFRC | 100/200)
0.35 - 0.510.26 - 0.40
CRF (NFRC | 100/200)
Forced Entry Resistance
ASTM 588
Type B Grade 10Type D Grade 10

Search: